The BP7 Series AC Variable-Frequency Power Supply is a high-performance power source designed to simulate grid voltages and frequencies worldwide. It provides stable and precise AC power for R&D and production testing across a wide range of applications, including home appliances, motors, and power tools.
AC Variable Frequency Power Supply
-
Input frequency
50Hz/60Hz ±5%
-
Frequency stability
<±0.1%
-
Transient recovery time
≤20mS
-
Source effect/load effect
≤1%
Product Description
Product Features
Models & Specifications
Single-Phase Output Models
|
Model |
Voltage |
Current (Low/High Grade) |
Power |
Dimensions (W×D×H) mm |
|
BP7010 |
Single-phase 0–300V |
90A/45A |
10kVA |
470 × 875 × 700 |
|
BP7015 |
Single-phase 0–300V |
136A/68A |
15kVA |
470 × 875 × 700 |
|
BP7020 |
Single-phase 0–300V |
182A/91A |
20kVA |
530 × 1010 × 800 |
|
BP7030 |
Single-phase 0–300V |
272A/136A |
30kVA |
530 × 1010 × 800 |
|
BP7045 |
Single-phase 0–300V |
408A/204A |
45kVA |
600 × 1210 × 900 |
|
BP7060 |
Single-phase 0–300V |
544A/272A |
60kVA |
600 × 1210 × 900 |
Three-phase output Products
|
Model |
Voltage |
Current (low/high) |
Power |
Size (WHD) mm |
|
BP7315 |
Phase voltage 0–300V Line voltage 0–520V |
45A / 22.5A |
15kVA |
600 × 1135 × 1010 |
|
BP7330 |
Phase voltage 0–300V Line voltage 0–520V |
90A / 45A |
30kVA |
600 × 1135 × 1010 |
|
BP7345 |
Phase voltage 0–300V Line voltage 0–520V |
136A / 68A |
45kVA |
700 × 1385 × 1240 |
|
BP7360 |
Phase voltage 0–300V Line voltage 0–520V |
182A / 91A |
60kVA |
700 × 1385 × 1240 |
|
BP7390 |
Phase voltage 0–300V Line voltage 0–520V |
272A / 136A |
90kVA |
750 × 1445 × 1385 |
|
BP73120 |
Phase voltage 0–300V Line voltage 0–520V |
362A / 181A |
120kVA |
800 × 1845 × 1450 |
|
BP73150 |
Phase voltage 0–300V Line voltage 0–520V |
454A / 227A |
150kVA |
800 × 1845 × 1450 |
|
BP73180 |
Phase voltage 0–300V Line voltage 0–520V |
545A / 272A |
180kVA |
800 × 1845 × 1450 |
|
BP73240 |
Phase voltage 0–300V Line voltage 0–520V |
724A / 362A |
240kVA |
800 × 2000 × 1450 |
|
BP73300 |
Phase voltage 0–300V Line voltage 0–520V |
908A / 454A |
300kVA |
800 × 2000 × 1450 |
Technical Specifications
|
Category |
Item |
Specification |
|
Input frequency |
50Hz/60Hz ±5% |
|
|
Output |
Output mode |
Three-phase standard mode, parallel single-phase mode, American standard two-phase mode, three-phase independent mode, three-phase unbalanced mode |
|
Output voltage - Range |
Phase voltage: Low grade:0–150V, High grade:0–300V |
|
|
Output voltage - Error |
+(0.2% read value +0.2% full scale value) |
|
|
Output frequency |
40–70HZ adjustable, 100HZ,120HZ,200HZ,240HZ fixed point |
|
|
Frequency stability |
<±0.1% |
|
|
Transient recovery time |
≤20mS |
|
|
Source effect/load effect |
≤1% |
|
|
Waveform distortion |
<1%(high/low voltage 220V/110V ±15%, resistive load) |
|
|
Overload capacity |
100%–110%, 5min;110%–150%, 1min;150%–200%, 5s;200%–300%, 2s; ≥300% Switch off the output immediately |
|
|
Protection function |
Over voltage, over current, overload, high temperature, short circuit automatic protection and alarm display |
|
|
Display |
Display mode |
7 inch touch screen |
|
Output voltage |
Resolution 0.1V; Display accuracy : ±(0.2% read value +0.2% full scale value) |
|
|
Output current |
Resolution 0.01A; Display accuracy : ±(0.3% read value +0.3% full scale value) |
|
|
Output frequency |
Resolution 0.1Hz; Display accuracy : ±0.1% |
|
|
Output power |
Resolution 0.01kW; Display accuracy : ±(0.45% reading value +0.45% full scale value) |
|
|
Features |
Shortcut Settings |
10 groups of voltage/frequency shortcut groups and can be customized |
|
Programming function |
Step mode, gradient mode, ladder mode |
|
|
Soft start function |
The initial voltage, operating voltage and boost time can be set. The boost time can be set to 1–99s |
|
|
Communication function |
Standard RS232; RS485 and network port communication are optional |
|
|
Resistance compensation |
0.000–0.500 euros |
|
|
Security |
Insulation impedance |
≥DC500V,10mΩ |
|
Voltage insulation |
DC2100V,10mA, 60S |
|
|
Cooling mode |
Forced air cooling |
|
|
Environment |
Operating temperature |
0 ~ 40℃ |
|
Relative humidity |
0–90%(non-condensing state) |
|
|
Altitude |
<1500m |
|
Applications
-

Home Appliances
-

Power Tools
-

Compressor
-

LED
-

Import and Export Equipment
-

Scientific Research Institutions
-

Motors
Up to 3× Overload Capacity
The overload capacity can reach up to 3×, significantly reducing the required power capacity for motor loads and lowering overall system costs.
Soft-Start Function
The starting voltage, frequency, and time can be configured to gradually ramp up the output voltage and frequency, effectively reducing inrush current during motor startup.
Soft-Start Output Mode
Programming – Step Mode
Up to 50 sets of output voltage, output frequency, and operating time can be configured, with up to 60,000 cycles supported. In-page looping is also available, providing flexible programmable variable-frequency power supply operation.
Step Output Mode
Step Programming Interface
Programming – Ramp Mode
The standard ramp function supports up to 100 sets of initial voltage, final voltage, initial frequency, final frequency, and ramp time. Up to 60,000 cycles can be configured for automated testing and programmable variable-frequency output.
Ramp Output Mode
Ramp Programming Interface
Programming – Stair-Step Mode
In Stair-Step Mode, users can configure the initial voltage, initial frequency, number of steps, voltage step (+/−), frequency step (+/−), and step time for flexible output control.
Stair-Step Output Mode
Stair-Step Programming Interface
Automatic Cable Voltage-Drop Compensation
The power supply automatically compensates for voltage drops in the output cables. By setting the cable impedance, the system automatically adjusts the output voltage to keep the voltage at the load closer to the set value.
Automatic Fan Speed Control
Two- or three-stage temperature-based fan control automatically adjusts the cooling fan speed according to no-load, light-load, and heavy-load conditions. This helps maintain low noise during light-load operation while providing sufficient cooling capacity under heavy loads.
7-Inch True-Color Touchscreen
The high-resolution 7-inch true-color touchscreen provides an intuitive interface and displays key parameters simultaneously, including set voltage, set frequency, output voltage, output frequency, output current, active power, reactive power, and power factor. Detailed alarm information is also displayed for easier monitoring, troubleshooting, and maintenance.
Remote Communication
The standard RS232 interface supports remote operation via PC, unattended operation, and integration into automated test systems. Optional RS485 and LAN interfaces are also available. Through the communication interface, users can start or stop the power supply, configure operating parameters, and monitor real-time operating status, parameters, and alarm information.